| Parameter | Mechanical Optical Switch | MEMS Optical Switch |
|---|---|---|
| Typical Switching Time | 10‑50 ms | 0.5‑5 ms |
| Typical Insertion Loss | 0.6‑1.2 dB | 0.8‑1.5 dB |
| Repeatability | ≤0.1 dB | ≤0.05 dB |
| Mechanical Lifetime | 5‑10 million cycles | >100 million cycles |
| Operating Temperature | ‑10 ~ +60 °C | ‑40 ~ +70 °C |
| Vibration Resistance | Medium | Excellent |
| Unit Cost(1×16 channel) | Lower | Higher |
For remote fiber monitoring system, switch lifetime is a decisive index. Monitoring system will execute automatic scanning test every several hours. High channel‑count systems accumulate huge switching cycles over years of continuous operation. Low‑lifetime mechanical switches will gradually degrade insertion loss and repeatability after millions of switching actions, leading to inconsistent OTDR trace data and false network alarms.
| Parameter | Mechanical Optical Switch | MEMS Optical Switch |
|---|---|---|
| Typical Switching Time | 10‑50 ms | 0.5‑5 ms |
| Typical Insertion Loss | 0.6‑1.2 dB | 0.8‑1.5 dB |
| Repeatability | ≤0.1 dB | ≤0.05 dB |
| Mechanical Lifetime | 5‑10 million cycles | >100 million cycles |
| Operating Temperature | ‑10 ~ +60 °C | ‑40 ~ +70 °C |
| Vibration Resistance | Medium | Excellent |
| Unit Cost(1×16 channel) | Lower | Higher |
For remote fiber monitoring system, switch lifetime is a decisive index. Monitoring system will execute automatic scanning test every several hours. High channel‑count systems accumulate huge switching cycles over years of continuous operation. Low‑lifetime mechanical switches will gradually degrade insertion loss and repeatability after millions of switching actions, leading to inconsistent OTDR trace data and false network alarms.